Pier Column Code Check T
This section creates code check templates for pier columns.
Steps
Step 1: Navigate to Pier Column Code Check Template
Navigate to Templates for Code Check and Load Rating > Pier Column Code Check in the tree view.

Step 2: Create Template
Enter the name PierColCCT in the Name column.
Step 3: Assign Load Combination Table
Click the three-dots icon on Load Combination Table and select SubstructureLCT.

Step 4: Configure Parameters
Set the following parameters:
Parameter
Value
Procedures for Shear Resistance (β and θ)
Generalized
Limit State for Shear Check
Strength Limit States
Interaction Diagram Limit State
Strength Limit States
Flexure Sign (Effective Shear Depth)
Use Critical Shear Concurrent Bending Moment



Step 5: Set State Provisions
Click the three-dots icon on Select State Provisions and assign FDOT.

Verification
After completing these steps, the Pier Column Code Check template is ready for use.
Last updated