Pier Cap/Bent Construction (Complete)

Navigation: Construction > Substructure Construction > Pier Capbent Construction Complete

For detailed parameter explanations, see the Pier Cap/Bent Construction (Complete) Reference.

Step 1: Click three-dots icon on Stage cell and select a Construction Stage as SubstrConstStage.

Step 2: As a result of these operations, an issue will appear on the OpenBrIM screen. This does not necessarily mean that any operation was done incorrectly. The issue will be resolved when the pier caps are define in the next step.

Quick Tip: Learn how to read issues

When encountering the warning as seen in OpenBrIM app, there is a "issue" , it is advised to review the parameters you have provided. This warning suggests that there might be a missing or incorrect parameter in your input. Check inputs to ensure they are accurate and complete.

When a warning is clicked, the reason can be displayed. The warning is expressed in the format of Component Group Name (can be viewed in the treeview) > User Defined Component Name (can be viewed in the spreadsheet name column) > Parameter Name (can be viewed in the spreadsheet column header).

After clicking on 'Superstructure > Connections > Bolted Field Splice' in the tree view, navigate to the Bolt category. Set the Bolt Property input. The issue will be resolved after these steps.

The screenshot demonstrates one example of two Bolted Field Splice components named BFS1 and BFS2 by the user, with parameter names Flange Bolt Property and Web Bolt Property.

Step 3: Click three-dots on the cell of the Pier Caps/Bents and pick all the pier caps.

Step 4: Keep the Self Weight Factor as default.

Pier CapBent Construction (Complete).mp4

Last updated