Step 1: Click on Name cell and set name as SStudCCT.
image-20250121-075823.png
Step 2: As a result of these operations, an issue will appear on the OpenBrIM screen. This does not necessarily mean that any operation was done incorrectly. The issue will be resolved when the load combination table is define in the next step.
Quick Tip: Learn how to read issues
When encountering the warning as seen in OpenBrIM app, there is a "issue" , it is advised to review the parameters you have provided. This warning suggests that there might be a missing or incorrect parameter in your input. Check inputs to ensure they are accurate and complete.
When a warning is clicked, the reason can be displayed. The warning is expressed in the format of Component Group Name (can be viewed in the treeview) > User Defined Component Name (can be viewed in the spreadsheet name column) > Parameter Name (can be viewed in the spreadsheet column header).
After clicking on 'Superstructure > Connections > Bolted Field Splice' in the tree view, navigate to the Bolt category. Set the Bolt Property input. The issue will be resolved after these steps.
The screenshot demonstrates one example of two Bolted Field Splice components named BFS1 and BFS2 by the user, with parameter names Flange Bolt Property and Web Bolt Property.
Step 3: Click the three-dots icon on the Load Combination Table cell, and then set SuperstructureLCT.
image-20250121-075840.png
image-20250121-075850.png
Step 4: Keep the Include Haunch for Section Properties? and Modular Ratio Comp. Method parameters as default.
image-20250121-075905.png
Step 5: You can edit the Fatigue parameters of Shear Stud Code Check from Fatigue Parameters tab.
Enter the ADTT as 1250**.**
Enter the Number of lanes available to trucks as 3.
image-20250121-075932.png
The completed shear stud code check template is illustrated below. Please verify that you have the same model on your end by examining each view provided here. For more information on how to perform visual checks, refer to the quick tips.
image-20250121-075954.png
image-20250121-080015.png
To view the entire procedure explained on this page, please watch the recorded Video below.