Pier Column Code Check
1
In this section, please specify which column or columns the code check will be applied to.
2
Navigate to Substructure Code Checks > Pier Column Code Check

3
Click three-dots icon on Pier and select as Column1 (As a different way, the relevant column can be selected on the 3D view by clicking "Pick".)
4
Click three-dots icon on Template. Select the PCCT1 "Pier Column Code Check" template defined in the previous steps for all.

5
Click three-dots icon on Section Data and click Edit. Section Data (parameters) appear in the combobox.

6
Click three-dots icon on Section and click Select. Select the "ColSec_P2" you want to code check for Pier Column (Column1).

7
Click three-dots icon on Stirrup Rebar Profile Set Stirrup Rebar Profile as ASTMA615No6.

8
Navigate back to Inputs tab. Set Tranverse Reinforcement Type as Tie.

The Pier Column Code Check have been created.
If icon won’t appear, collapse page tree menu by clicking on arrow or using shortcut “[”.
Pier Column Code Check
Inputs
Section Data
<br>PCC3 PCCT1 Column1 [[ColSec_P2, 0, ASTMA615No6, 6, 2, 2]] 0.003 0.75 0.005 0.9 Tie<br>
<br>ColSec_P2 0 ASTMA615No6 6 2 2<br>