For the complete documentation index, see llms.txt. This page is also available as Markdown.

Pier Column Code Check

Navigation: Substructure Code Checks > Pier Column Code Check

For detailed parameter explanations, see the Pier Column Code Check Reference.

Step 1: In this section, please specify which column or columns the code check will be applied to.

Step 2: Navigate to Substructure Code Checks > Pier Column Code Check

Step 3: Click three-dots icon on Pier and select as Column1

(As a different way, the relevant column can be selected on the 3D view by clicking "Pick".)

Step 4: Click three-dots icon on Template.

Select the PCCT1 "Pier Column Code Check" template defined in the previous steps for all.

Step 5: Click three-dots icon on Section Data and click Edit.

Section Data (parameters) appear in the combobox.

Step 6: Click three-dots icon on Section and click Select.

Select the "ColSec_P2" you want to code check for Pier Column (Column1).

Step 7: Click three-dots icon on Stirrup Rebar Profile

Set Stirrup Rebar Profile as ASTMA615No6.

Step 8: Navigate back to Inputs tab.

Set Transverse Reinforcement Type as Tie.



If icon won't appear, collapse page tree menu by clicking on arrow or using shortcut "[".

Pier Column Code Check

Inputs

Section Data

```

PCC3 PCCT1 Column1 [[ColSec_P2, 0, ASTMA615No6, 6, 2, 2]] 0.003 0.75 0.005 0.9 Tie

```

```

ColSec_P2 0 ASTMA615No6 6 2 2