Pier Column Code Check

Navigation: Substructure Code Checks > Pier Column Code Check

For detailed parameter explanations, see the Pier Column Code Check Reference.

1

In this section, please specify which column or columns the code check will be applied to.

2

Navigate to Substructure Code Checks > Pier Column Code Check

3

Click three-dots icon on Pier and select as Column1 (As a different way, the relevant column can be selected on the 3D view by clicking "Pick".)

4

Click three-dots icon on Template. Select the PCCT1 "Pier Column Code Check" template defined in the previous steps for all.

5

Click three-dots icon on Section Data and click Edit. Section Data (parameters) appear in the combobox.

6

Click three-dots icon on Section and click Select. Select the "ColSec_P2" you want to code check for Pier Column (Column1).

7

Click three-dots icon on Stirrup Rebar Profile Set Stirrup Rebar Profile as ASTMA615No6.

8

Navigate back to Inputs tab. Set Tranverse Reinforcement Type as Tie.



If icon won’t appear, collapse page tree menu by clicking on arrow or using shortcut “[”.

Pier Column Code Check

Inputs

Section Data

<br>PCC3 PCCT1 Column1 [[ColSec_P2, 0, ASTMA615No6, 6, 2, 2]] 0.003 0.75 0.005 0.9 Tie<br>

<br>ColSec_P2 0 ASTMA615No6 6 2 2<br>

Last updated