Lateral Bracing
This section defines horizontal lateral bracing in the top flange plane of the tub girders.
Steps
Step 1: Navigate to Lateral Bracing
Navigate to Bracing > Lateral Bracing in the tree view.

Step 2: Assign Girder
Click the three-dot icon on the Girder cell and set G1 to place bracing inside that girder.
Step 3: Define Bracing Stations
Enter Left Web Station and Right Web Station values (along PGL):
Example for LB1: Left Web Station = 3 ft, Right Web Station = 10 ft


Step 4: Assign Section
Click the three-dot icon on the Section cell, select Select, and choose AISCWT6X29.

Step 5: Complete All Bracing Members
Define left and right stations for all lateral bracing members on G1 and G2 girders.

Step 6: Optional Gusset Plate Settings
Modify the Gusset Plate tab if desired. Changes affect 3D visualization only, not the FEA model.

Verification
The completed lateral bracing is shown below.



Last updated