Project Requirements (IDS)
Owners now state what a delivered bridge model must carry as IDS files (buildingSMART Information Delivery Specification 1.0). An example is the usBridge 2.0 set: the five .ids files of the IDM for the Design-to-Construction Data Exchange for Highway Bridges v2.0.
OpenBrIM keeps these files in the project and checks the model against them. At any time you can see:
what each object must carry;
what is satisfied, missing or failing;
which object and which field fixes each gap.
When you export the IFC, the file itself is checked before it is saved, and a report can be saved with it.
The results go into a compliance report and into BCF issues for a BCF tool.
What You Need
The owner's IDS files. For usBridge 2.0 these are
usBrSpec_General.ids,usBrSpec_SpatialBreakdown.ids,usBrSpec_Classes.ids,usBrSpec_PropertySets.idsandusBrSpec_AbV Exclusions.ids.Optional reference files that come with them, kept with the set: PDFs such as the IDM, a design manual or special provisions, and spreadsheets such as the data dictionary workbook or the owner's pay-item list.
A project whose model compiles. The check needs the compiled model.
A project checks only against the IDS files you add to it: the owner's own copies. The Library's Delivery requirements tab shows the usBridge data dictionary for reference; it does not add anything to a project.
Which IDS an export follows: the IFC Hierarchy setting
Every IFC export follows one IDS, shown as IFC Hierarchy in the IFC Export Settings of the Export dialog (and as the IFC Hierarchy column of an Export File, and IdsSelectionGet / IdsSelectionSet for agents). The list offers:
the library default: the usBridge delivery requirements of the Library's Delivery requirements tab, with the OpenBrIM Standard layer when the library has one (shown as OpenBrIM Standard (library default), else usBridge Data Dictionary 2.0 (library default));
every requirement set you added that has an IDS file (an inactive one is marked, and still followed when chosen);
every other delivery-requirements object of the library, marked (library);
your own requirements drafts on your library branches, marked · Draft (branch) as the Delivery requirements page marks them, without switching the session to that branch. A draft is read from your own branches: anyone else who opens the project sees it as (missing, using default), unless they have a library branch of the same name holding that object (a copy of their own, or yours once they check out your branch link and switch to it), which they then read instead.
When you add an IDS set, the export follows it from then on, and the message after the import says so. A second import does not replace a set you chose: the message says the export stays on it, and you change IFC Hierarchy when you want the new one.
The file is written as the chosen IDS says, and checked against every active set. Check now writes the same file an export following the project's IFC Hierarchy writes, so its statuses are the ones that export's delivery check will find. An Export File (or an agent export) with an IFC Hierarchy of its own is written as that one says and checked as written when it is exported; Check now does not check that file. With several sets active, a set that is not the chosen one can fail on what the chosen one writes. Choosing the library default while a set is active keeps the set checked and writes the file in the library's format. The IFC tab and the forms offer the fields of the chosen IDS; a set that is checked but not chosen adds its statuses to those fields.
A chosen set that is later deleted shows as (missing, using default) until you pick something else. An Export File's own IDS that is deleted shows as (missing, using the project's); one that is deleted or cannot be read when the file is exported is named in the export's report, and the file follows the project's IDS. A project saved before this setting existed keeps the typing it had: with one active IDS set it follows that set; with several active it follows all of them together, shown as All active IDS sets (N), until you pick one (or add another IDS, which is then followed); with none, the library default.
Without an IDS: the library default
Until a project has a requirement set with IDS files, its IFC follows the library default: the OpenBrIM Standard where the library has it (OpenBrIM's own definition, a data dictionary layer on usBridge 2.0, maintained by OpenBrIM), otherwise usBridge 2.0 itself with OpenBrIM's corrections. It decides how the export arranges the bridge (with the OpenBrIM Standard: bays between girders, approach structures in their bridge, girder segments as IfcBeam parts of their girder) and which properties the IFC tab and the forms offer. It is a format, not a requirement: nothing is checked against it, and there are no statuses, report or warnings about missing values. Turning every IDS set off puts the last check's statuses aside, since nothing is checked any more. They come back, out of date until you check again, when a set is turned on. The export keeps following the IDS chosen in IFC Hierarchy, even a set that is now off; a project that never chose one returns to the library default.
Add Requirement Files
Requirement files live in Docs, in a folder named Requirements. Each group of files is a requirement set (for example US Bridge Design-to-Construction 2.0). The Requirements folder is created the first time you add files and is always shown at the top of the Docs tree.
From Docs
Click DOCS. in the left sidebar.
Select the project at the top of the tree and click Add requirements… (or use + on the project row). Once the Requirements folder exists, its own + and Add requirements… do the same.
Pick the files. A requirement set takes
.ids,.xml,.pdf,.csv,.xlsxand.xlsfiles.Review the preview (below) and click Add to project.
The Requirements panel then opens on the new set.
Other ways in
The Requirements panel: click + (Add requirement files…) in its header.
The Export dialog: when the project has no requirement set, the IFC settings show Check against: no requirements · Add requirements….
A set that already exists: use Add files… on the set (in Docs or in the panel) to add more files to it.
Drag and drop
You can drop files from your computer onto the Docs tree or onto the panel.
The Requirements folder
Adds the files as a new requirement set (through the preview).
A requirement set
Adds the files to that set (through the preview).
An IDS file in a set (one .ids file)
Asks Update “…”?: Update… replaces the file's content after showing what changes; Add as another file adds it beside the old one.
Any other Docs folder
.ids files ask Add as requirements?: Add as requirements or Upload as plain files. Other files upload as usual.
The Requirements panel
Onto a set's block: adds to that set. Elsewhere: a new set.
Files of other types dropped on a set are skipped with a message.
The add preview
Before anything is uploaded, the Add requirement files dialog reads the files and shows what they do in this model:
New requirement set: the Title of the set. For the five usBridge files it suggests the shared milestone and version, US Bridge Design-to-Construction 2.0. The files go into a folder of this name under Requirements in Docs.
Files: each file with its IDS title, version, author, date, purpose and milestone, its role chip (IDS rules or Reference) and its number of rules. A file that cannot be read as IDS says why.
What it checks: how many rules are checked from the model's data, how many against what the IFC exporter can write, and how many read geometry and are checked at export.
In this project: how many objects in this model the rules check, the result If added now (passing, missing, failing, not applicable, checked at export) and the IFC products by class. Objects exported without a specific IFC class are listed, because rules written for specific classes do not apply to them.
Problems in the files: defects found in the IDS files, each marked Error, Warning or Note.
Fixes for problems in the files
IDS files from owners sometimes contain mistakes. OpenBrIM checks every file against the IFC 4.3 schema and against the other files of the set. Where a mistake can be corrected, the preview shows a ticked Fix: line.
A ticked fix is saved with the project and applied whenever the rules are read. The file itself is never changed.
Untick a fix to keep the rule as written.
After adding, the fixes are listed on the file's Issues tab in Docs, where you can Accept fix, Dismiss or Undo each one.
Problems found in the usBridge 2.0 files include:
the pier-cap rules name
usBrPset_Piercap, while the property set is defined asusBrPset_PierCap, so those rules never apply;the Counterfort rule names a property set called only
usBrPset;the DeckSegment rule requires
UsageType = LOGITUDINAL, which is not a valid IFC value, so every deck segment fails it;the allowed assembly types include
HELICAL_ANHCOR, while the Helical Anchor rule usesHELICAL_ANCHOR;the property set name
usBrPset_Expansion Jointcontains a space;some allowed-type lists lack values that other rules use (for example TIEBAR and STRUCTURALCABLE for IfcMember).
The preview and the Issues tab show which of these have a fix.
Where the Requirements Live (Docs)

Docs shows the tree on the left and the selected item on the right.
The Requirements folder shows its sets, each with an Active switch, and the status of the last check with Check now (or Check again). Its buttons are Add requirements…, Open panel, Make folder searchable by AI and IFC structure…. Compliance reports and BCF files saved to Docs go into its Reports folder.
A requirement set shows where it came from (Uploaded here or From another project), its version, its files and its rule count. Its settings are:
Active: Check now checks this set. Turn it off to keep the files without checking them.
Required for delivery: an IFC export is not saved while this set's rules fail. Otherwise the export only warns.
The set's ⋯ menu: Add files…, Show in panel, Active (checked by Check now), Required for delivery, Rename…, Make folder searchable by AI, Remove set…. Its + offers Add files….
A file's ⋯ menu:
an IDS file: Update… and Download readable version;
every file: Change role…, Download, Share…, Rename…, Signatures… and Remove from set….
Rename… keeps a requirement file's extension (.pdf, .ids): the extension says what the file is, so a new name that ends differently is refused, and the dialog says why. Dots, dashes, spaces and emoji in the name stay; characters a file path cannot hold (/ \ : * ? " < >) become spaces. Any other Docs file keeps its extension too. For every Docs file, a name that is only the extension (.pdf) is refused: A file needs a name before .pdf. A file with no extension cannot take a name that a formula would read as a reference: a name that starts with a digit becomes NewObj1, and an analysis object type such as Node or a workflow parameter's name gets a number (Node1). This applies to requirement files too.
Removing a set or a file asks first and says how many rules leave the project's checks.
File roles
Each file has a role, guessed from its name. Change it with Change role… or the Role in the set selector.
IDS (checked rules)
.ids, or an .xml file that holds IDS
The rules the model is checked against.
Reference
every other file: .pdf, .csv, .xlsx, .xls, and .xml files that are not IDS
Kept with the set. Use Make searchable by AI so the AI assistant can read it.
The IDS file pages
Select an IDS file in Docs to see four tabs.
Overview: the file's information (title, version, author, date, purpose, milestone, description, copyright, IFC versions), its rule counts (required, apply where present, prohibited, format rules), how they are checked, the checks of the file itself, and the file's status in this project.
Rules: every rule in plain language. Each rule reads Applies to, then Must, May or Must not lines, with the file's instructions where it gives them. Search, and filter by object type, cardinality (Required, Where present, Prohibited) and status in this project. A rule changed by a saved fix is marked Fixed.
In this project: each rule with the objects it applies to and their status. Filter by Missing or failing, Passing or All rules. Select in 3D / Select all N selects the objects; Edit IFC · IDS properties… opens an object's form.
Issues: the problems found in the file, with their fixes.

Check the Model
Once a project has a requirement set, a tab labeled IDS appears on the right edge of the window, below the AI tab. It shows the last result, for example IDS 69%, with a red badge for the number of failing rules. Click it to open the Requirements panel. You can also use Open panel in Docs or Show in panel on a set.
Open the project. When it has an active requirement set, the model is checked once by itself, as soon as it is compiled and the window is idle. On a large model it is not: the panel says Large model: the check did not run automatically — click Check now. To check again later, click Check now. The check exports the model internally (without geometry) and tests it against every active set. It takes a few seconds, longer on a large model.
Read the summary at the top of the panel.

The large percentage is the share of data rules that pass, out of those the model was checked against. The counts under it are:
passing
Every applicable object meets the rule.
missing
Something the rule requires is absent or blank.
failing
A value is wrong, or something the rule prohibits is present.
checked at export
The rule reads geometry, so it is checked when the IFC is exported.
not applicable
The rule applies to nothing in this model.
File format rules are counted on their own line. These are rules that ban an entity from the file (for example the usBridge AbV Exclusions file). Most are settled by how OpenBrIM writes IFC, not by the model. A ban on a geometry entity that the IFC writer never produces passes at once; a ban on one it can produce is checked at export.
When the check cannot run
The check needs a compiled, loaded model. If it is not ready, the panel says why:
The model is compiling. or The project is still loading.: the check waits and runs by itself when the model is ready. Click Don't wait to stop waiting.
The compiled model is waiting to be loaded.: click Load Model (in the 3D view alone or the FEA view: the button is not shown while the 2D plan is on screen), then check again.
Compiling is on hold.: release the hold, then check again.
The model did not compile: some inputs failed validation.: fix the inputs listed, then check again.
The requirement files could not be read, so nothing was checked.: the message names each file and why.
Read the Results
Each set in the panel shows its title, version, origin, Active switch, Show in Docs and Add files…. Below come its percentage, a line per IDS file and the result list.
Required, but not found in the model lists rules that need an object the model does not have, for example a rule that requires an IfcProjectedCRS when the project has no coordinate system.
The other groups are by IFC class and object type, for example IfcBearing · Bearing Fixity (16) — 16 missing. Failing groups come first.
Expand a group to see its objects, and an object to see each rule with what is not met, the value found (Now:) and the rule's instructions. Requirements that are met are folded under + N requirements met.
The crosshair button selects the objects in the 3D view. The pencil button (Edit IFC · IDS properties…) opens the object's form.
When one OpenBrIM object exports several IFC elements (a pile layout, a girder's plates), the group says so, for example 44 IFC elements from 4 model objects.
Quick fixes
An expanded group with missing or failing objects starts with a Fix: line. It offers only the fixes that apply:
Set values on N …: one field per value the objects miss or fail, written to all of them at once.
Enter project information…: for the project's own entities (IfcProject, IfcSite, the facility).
Open the sheet: selects the objects and opens their IFC tab in the data window, opening the data window first if it is closed. It is offered only for a type whose sheet has that tab; a type with no IFC properties, such as a Support Line, has none. When the data window does not come to that tab, a message says why: select one of the objects and open the tab yourself.

Each value is written all or nothing per object, and one fix is one undo step. Check again to see the new results.
Color the model by status
Under the summary, switch on Color the model by status (available after a check). The 3D model is painted from the last check: failing red, missing amber, passing green, and objects no rule applies to dimmed. A legend gives the counts. An object's color is its worst status over the rules. The badges in the tree (below) count the same way.

The colors are not saved in the project. They are cleared when the panel closes. If the model changes after the check, the legend says the colors are out of date.
IFC structure
IFC structure… (in the panel and on the Requirements folder in Docs) opens a window with the spatial structure of the exported IFC: Project › Site › Bridge › parts, each with the elements it contains, grouped by class and predefined type, and the status counts of each. Click a row to select its objects in 3D.
Where an element goes is set by its library object: its place in the bridge (superstructure, deck, deck segment, pier or abutment, foundation, bearing, approach or retaining structure), the support line it stands on and the bridge it belongs to. A pier or abutment is grouped by its support line, in station order, and is an abutment when an object on that line is placed as one. To move an element, change the library object; there is no per-object setting. When the export cannot place an element, its warnings name the object type and why.
By default the export writes:
A project whose objects come from a library version older than this layout keeps one shared Approach Structure until it takes the library update.
Two kinds of object have a second place that the active requirement sets can ask for. A cross frame can go in a Bay between the two girders it connects ("Bay G1 - G2"), and a strip seal can go in its approach slab's structure. The export uses the second place only when an active requirement set requires it, for example an owner's IDS whose rule says cross frames are contained in an IfcBridgePart BAY. usBridge 2.0 requires cross frames in the Superstructure and strip seals in the Superstructure, the Deck, a deck segment or a culvert barrel, so with only usBridge active they stay there. When two active sets ask for different places, the object stays in its first place and a warning names both rules: leave the set you do not deliver to inactive.
To make an owner's IDS with its own placement rules, for example a PennDOT IDS that groups cross frames by bay, start from usBridge 2.0 in the Library:
Open the Library's Delivery requirements tab and choose the owner under Owner agency (or New owner agency…).
Open the entry, for example Cross-Frames. Its IDS rule line shows where the IDS says it must be: contained in an IfcBridgePart SUPERSTRUCTURE. Click Change for PennDOT.
Edit the values. Type the new value over the old one (SUPERSTRUCTURE → BAY). Where the rule lists several values ("one of"), remove one with × or add one with + Add a value. For example, PennDOT's strip seals sit in their approach structure, so in the Expansion Joint rule change DECK to APPROACH_STRUCTURE and remove SUPERSTRUCTURE and DECK_SEGMENT. Give the reason and click Apply. The rule then shows each change with the usBridge value it replaces; Undo PennDOT's change puts usBridge's values back.
See the changes lists every change with the checks, then Save (or Improve on a branch for a reviewer to merge).
Export IDS downloads the usBridge files with the owner's changes. Add them to the project as a requirement set (Add Requirement Files) in place of usBridge 2.0. The IFC export then places cross frames in bays and strip seals in their approach structure.
The Library already holds a PennDOT owner agency with these changes, read from PennDOT's SR6 delivery: cross frames in a bay between the girders they connect (with BAY added to usBridge's list of bridge part types, which every bay must pass), and strip seals in their approach slab's structure. Choose PennDOT under Owner agency and click Export IDS for PennDOT's IDS files.
A culvert is not a bridge: as usBridge 2.0 asks, each culvert is a Culvert structure in the site's Structures facility, with a Barrel holding its culvert units (IfcBuiltElement CULVERT_UNIT) and an Inlet/Outlet for objects placed at its ends; the culvert's fill sits in the culvert structure. An object placed in a culvert that is set not to export goes to the site, with a warning.
An object writes an IFC element only when its library object defines one. A project in which no object defines one, such as a project of plain shapes, is exported flat instead: every object as it is, in one bridge named after the project, without a spatial structure, with a warning that says so. As soon as one object defines an element, the export writes the structure above, and objects that define none are left out.
To leave an object out of the IFC, set Export to IFC? to No on its IFC tab. The export then writes neither the object nor its parts, in every export mode, and the requirement sets ask nothing of it. It also stops being a bridge or a culvert that other objects can be placed in, and it does not count toward the size limit of the check that runs after a project opens.

Badges in the tree
After a check, the tree in the data window shows badges on object types whose objects fail or miss something, for example 2 missing. Badges turn grey when the check is out of date. Click a badge to open the panel showing only that type (Showing … only, with Show all to clear the filter).

Enter Values
Requirement values are stored in the project, outside the library objects, so they survive library updates. Entering values does not recompile the model and does not invalidate analysis or design results.
Values are kept by the object's name, the one thing that identifies an object for good. Renaming an object takes its values with it, and undoing the rename takes them back; this includes renames a library update makes.
An object whose name contains
#or starts with@cannot hold values: rename it first.While two objects share a name, neither holds values: the form and the sheet say so, and the IFC export writes the values on neither and warns. Rename all but one; the values stay with the object that keeps the name.
Deleting an object leaves its values in the project, and an object created later with the same name takes them. Renaming another object to that name does not: those values are set aside while it holds the name, and come back when it leaves it.
You enter every requirement value: nothing is read from the object's parameters or from analysis results.
When a property has no value but the last check found one in the exported file (one a library object writes itself, an IFCParam), the field shows it greyed with the chip in the model. A value you enter replaces it in the export.
Project and delivery information
Click Project information… in the panel header (or Review… on the Docs banner). The form has these sections:
Project (IfcProject): for usBridge,
usBrPset_ProjectCommonwith ProjectNumber, LettingDate, ModelVersion, ModelPreparationDate and others.Site (IfcSite).
Bridge: one section per bridge object, titled with its name: identification, geometry, design loading.
Delivery: written once per IFC file: the person and organization (with their roles), the classification system (see Classification) and the coordinate system datums.
For the person and organization, the form offers your OpenBrIM account details but does not fill them in. Click Use my account details to take them; they are saved when you save.

One object
Open the form with the pencil button in the panel, Edit IFC · IDS properties… in Docs, or Edit IFC · IDS properties of … in the data window. The dialog's title is IFC · IDS properties: followed by the object's name and type.
Fields are grouped by property set; required sets come first, optional sets are folded under Show N optional property sets.
Required properties are marked with *. Each field shows its IFC data type, the allowed values and the IDS rule's instructions when it gives them.
After a check, each field shows the check's verdict: passing, missing, failing, not in the export (stored, but the export did not write it), or not checked yet after you change it.
Clear removes a value when you save.
Save checks every field first. A field that cannot be saved says why, and nothing is written until all fields are valid. The message after saving says how many required properties are still empty.
A part made by a library object (an inherited stiffener, an exported child) holds no values of its own. Enter them on the object it belongs to; they apply to its parts.

Many objects: the IFC tab
The IFC tab in the data window holds all of an object type's IFC data: its Type, Predefined Type and Export to IFC?, then the properties the project's IDS files (or, without them, the OpenBrIM Standard) ask of that type, then the properties added beside them.
Rows are the type's objects (narrowed by the 3D selection, as on other tabs). The first columns are Type, Predefined Type and Export to IFC?, edited as before (the Predefined Type list offers only what the IDS or the OpenBrIM Standard allows). Then the properties asked for, required ones first and marked *; Show optional adds the rest. A part row has no Type of its own.
The strip above the sheet has two filters: Property set shows the columns of one property set, or of All property sets (it names each set without its prefix:
usBrPset_PayItemQuantitiesreads PayItemQuantities; two sets that would then read the same keep their full names); Show optional adds the optional properties' columns (one with a value always shows). Your choices are kept for the object type on this computer. Before a check, the columns come from each object's IFC class; after one, from the check.A column header gives the property and, for a measure, its unit, for example SubstructureSkewAngle * and [°]. It does not name the property set: choose one in Property set to see which set a column belongs to.
Cells show the object's own value. An empty cell shows greyed, tagged model, what the last check found in the exported file. A cell that does not apply reads N/A. Cells are not colored by the check: its results are in the panel, the forms and the 3D colors.
The cell menu offers the allowed values (or Choose a value… for long lists), Clear … and Edit IFC · IDS properties of ….
The column header menu offers Clear … for the whole column.
Paste from Excel: copy a block of cells in Excel and paste it into the sheet. Every cell is checked. Values that cannot be stored are listed together under Paste: some values were not stored, each with the reason. The IFC tab never adds or deletes objects.
Rows that are parts of library objects are read-only and show the values of the object they belong to.
Properties of your own
A property no requirement set asks for can still go into the IFC: an owner's internal field, or a property of a set an IDS leaves open ("any property of …").
In the object form, Added by you lists them after the asked properties. Add property asks for the property set, the property and its IFC data type (IfcLabel for text, IfcLengthMeasure for a length, and so on). Type the value in the new field and save.
When an IDS asks for any property of a set, the form's note offers Add one to that set.
In the IFC tab, Add property (at the right of the strip) adds one to every object shown that has no value for it yet. Its column comes after the asked ones, headed added; edit, paste and clear it like the others. It is offered once a requirement set is active or the project follows the OpenBrIM Standard. The tab shows the object's inputs at once; while the definition is being read, the strip says Reading the IFC definition… and its columns are added when it is read.
The IFC carries each value as entered, with the data type you chose. The check has no rule for it. A value kept from a requirement set you turned off is listed here too: the export still writes it.
Not accepted: a property the requirement sets already ask (enter it in its field), a property set the object must not carry,
IfcClassificationReference(codes have their own fields), and a property in a set namedPset_…orQto_…that the requirement sets do not name: those names are buildingSMART's standard sets.
The IFC tab no longer has a Properties input: add a property of your own as above. Properties a project entered there before are not written.
Classification
When an IDS requires a classification (the usBridge Classes file asks one of every element, in any system), each object gets a field for its code:
IfcClassificationReference · Identification when the IDS leaves the system open. The code belongs to the delivery's own classification system: enter that system's Name, and if you like its Source, Edition and EditionDate, once in Project information under Delivery (IfcClassification). Without a Name, codes are not written and the export says so.
IfcClassificationReference · the system's name when the IDS names the system. The code is written under that system.
In the IFC file each code becomes an IfcClassificationReference related to the object. A part given a code of its own is classified by that code, not by its role's.
Pay-item properties such as usBrPset_PayItemQuantities PayItemReference, UnitOfMeasure and PayQuantity are ordinary properties: one value each.
PredefinedType and IFC class
An object's IFC class and predefined type are on its IFC tab (Type and Predefined Type). In a project with requirement sets:
the Predefined Type list offers only the values the active IDS files allow for that class;
USERDEFINED… asks for the name of the user-defined type (letters, digits and _), which is written as the object type;
a current value the files do not allow is shown as … (not allowed by …) and is not replaced unless you choose another.
The export writes the class in the object's Type and Predefined Type; their defaults come from the library object, and there is no project-wide class map. Both are saved with each object, so updating the library does not change the class of objects already in a project: change them on the object, or place it again. An object saved with a spatial class inside a bridge part (an abutment saved as IfcBridge) is written as IfcBuiltElement, with a warning to change its Type. A road keeps its IfcRoad class and is written as a facility of the site. The IFC tab reads an object's class as the IFC export writes it, before and after a check. A predefined type the class does not have (a footing stored as FOOTING, a girder stored as IfcBeam GIRDER) is written as the library default, with a warning to set it.
Parts of an object
Some library objects can be written as several IFC elements. A steel plate girder can be written as the girder assembly, one girder segment per field segment, and each segment's top flange, web and bottom flange plates. The library object says what its parts are and their IFC classes, and the export writes every part it declares.
For a steel plate girder:
the girder is written with its own class; each segment is an IfcElementAssembly with the object type GIRDER_SEGMENT, part of the girder and also placed in the Superstructure (usBridge's "Girder Segment (Built-Up Steel)" asks for that); each plate an IfcPlate FLANGE_PLATE or WEB_PLATE, part of its segment;
in the IFC tab, each girder's row is followed by one row per part: G1 · Segment, G1 · Top Flange, G1 · Web, G1 · Bottom Flange. Each row has its part's class and the columns the IDS asks of it;
a value entered on a part row is written on every part of that kind of the girder (all of G1's top flanges); the girder's own values stay on the girder;
when a girder has more than one part of a kind (one per field segment), that kind's row is followed by a row per part: G1 · Top Flange · Start, G1 · Top Flange · from SP2 (the field splice the segment starts at). Enter there what differs between them, such as a flange's thickness transitions. Until a part has its own value it shows the kind row's, in grey and tagged shared; the export writes the part's own value over the shared one;
each plate is written with its own material (the girder's top flange, web or bottom flange material).
A segment is identified by the field splice it starts at, so renaming a splice keeps its parts' GlobalIds and values, and adding a splice renumbers nothing. The first segment, which starts at no splice, is identified as Start; an object named Start is a different thing, and renaming it moves nothing of the girder's.
Parts come from the library object version the girder uses: once a project takes the library update that declares them, every girder has them. A built-up plate girder has them; a rolled section is written as one element.
Units and formats
Numbers are typed in the project's units (the data window's Input Units... preset if one is chosen). They are stored in SI. A measure OpenBrIM has no unit type for, such as a velocity, is typed in SI.
A mass is typed in the mass of the project's force unit when that is a US one: lb, kip (1000 lb), long ton (T) or short ton (ST). Otherwise it is typed in kg. A formula that reads a weight gives its mass under standard gravity. A formula that reads both a mass and other measures, or reads values through a lambda or a call, is refused, because it is not known whether it gives a mass or a weight. A mass formula entered before this version keeps reading its numbers in kg.
Dates are YYYY-MM-DD.
A property the IDS states takes several values takes them separated by
;.Some lists take an exact number of values.
Pset_BearingCommon.DisplacementAccommodatedandRotationAccommodatedtake three: X, Y and Z in the bearing's local axes. The form shows one checkbox per axis; the sheet's cell menu offers Set X, Y, Z…, or typetrue; false; true. A list with the wrong number of values is refused.Values are checked against the IDS data type and every restriction (allowed values, patterns, bounds). A value that does not meet them is refused with the reason; it is never changed to fit.
Export the IFC
Open the project menu in the top bar and choose Export….
In Export Data, set Data to 3D Model and Format to IFC v4.3 Format (*.ifc).
Check IFC Hierarchy: the IDS the file follows (see Which IDS an export follows). It is your imported set once you added one, else the library default; pick another entry to write the file in that format. A library entry is written, never checked: the Requirements section then says so, and still checks the file against your active sets.
Check Units: SI (m, N, kg) or US (in, kip, lb). It starts on the project's own units (US when its lengths are in inches, feet, yards, miles or US survey feet), and keeps your choice for that project until the page is reloaded. Either file is read the same by other software and by the requirements check: the file names its units and their ratio to SI.
Keep Include Quantities, Set Coordinate System and Export Alignments on. Most requirements read the quantities, coordinate system and alignment, and the property sets, which every IFC export writes (there is no option to leave them out; an Export File saved with Include Property Sets set to NO now writes them too). All three are on by default, also for an Export File saved before this version that never stored Include Quantities or Export Alignments: such a file now writes quantities and alignments.
Check the Requirements section:
Check against names the active sets and the last Check now result, with Open for the panel.
Attach report saves the requirements report (
<name>.requirements.html) next to the IFC. The browser may ask once to allow two downloads.Check: the Skip the requirements check box saves the file without checking it and without a report. It is off each time the dialog opens. Checking reads the whole file back, which takes a while on a large model. When a set is marked Required for delivery, skipping the check overrides that set, and the note under the checkbox says so.
Click Export.

Unless you skip the check, the file is written, and that file is checked against every active set, every rule, geometry included. Then:
The file passes: it is saved, with its report.
The file does not pass: the dialog lists the sets that fail, their counts and the first rules that do not pass. Choose Export anyway, Cancel or Open Requirements panel.
A set marked Required for delivery does not pass: the file is not saved. The dialog says Not exported: … and offers Save report, Open Requirements panel and Close. To export, fix what fails, turn off Required for delivery on the set in Docs, or export again with Skip the requirements check, which overrides it. A file that could not be checked at all is also not saved while a set is required for delivery.
The check was skipped: the file is saved without a report. The message says Exported … without the requirements check., and names any set marked Required for delivery that this overrides.
When rules do not pass, the outcome also offers Download BCF issues: those rules as BCF topics that select their elements in the file just written (see BCF Issues).

Large files. A file over about 100 MB is not read back. The model's export without geometry, written with the same options, is checked instead: data rules are checked as in the delivered file, and rules that read geometry are not checked. A rule that was not checked never counts as passing:
A set marked Required for delivery with such rules blocks the export. Export with Skip the requirements check to override it.
Any other set with such rules gives a warning, and the message says how many rules were not checked.
A ban on geometry that OpenBrIM does write, such as
IfcTriangulatedFaceSetin the AbV exclusions, fails, because the delivered file has that geometry.
The dialog, the message after the export and the report say how the file was checked.
The report lists the summary per set, every rule that does not pass with the objects concerned and why, the values that need analysis or design results, files that could not be checked, and the export's own warnings. Owners and reviewers can open it in any browser.
IFC files written from the data window's Export File tab (Sync to Local Disk) go through the same check. It cannot be skipped there: the export runs without a dialog, so a set marked Required for delivery is never overridden by a setting nobody sees. When a required set fails, the file on disk is not changed and the report is saved beside it. When the file does not pass, it is written with the report beside it. A file that passes is written without a report. The export's own warnings, such as a coordinate system with no project location, open in their own dialog. A file path with folders (Bridges/North/Model.ifc) is written into those nested folders; earlier versions wrote it into the last folder only, under the project's folder, so the file now appears in a new place and the old copy is left as it was.
Compliance Report
The compliance report states whether the model meets the IDS rules of the project's requirement sets. Owners and reviewers can read it in any browser or as a PDF.
In the Requirements panel, open the ⋯ menu and choose Compliance report….
If there is no check yet, or the last one is out of date, the model is checked first. The dialog then says (checked again for this report).
The dialog shows the verdict, the figures and a preview of the report.

Complies
Every active set passes.
Not shown to comply: the check is out of date
The model or the requirements changed after the last check, and the model could not be checked again, for example because it is not compiled. Or they changed while the check for this report was running. Red when a set is required for delivery.
Does not fully comply
A set does not pass: a rule fails or misses information, or a requirement file cannot be read.
Does not comply
A set marked Required for delivery does not pass, or the model could not be checked while a set is required for delivery.
Rules that read geometry are checked when the IFC is exported, not in this report.
An out-of-date check never makes the report say Complies. The reasons say when that check was made, why the model could not be checked again, and what the check found then. The rest of the report shows that check as it was. Compile the model and make the report again to report on the model as it is now.
The report holds:
the project, when it was checked, what was checked, the requirement sets, Prepared by (your name and e-mail) and when the report was made;
the verdict and its reasons;
Summary, one row per set, and Rules that do not pass, with the objects concerned;
requirement files that could not be checked, and the export's warnings.
Then:
Save to Docs saves the report in the project, under Requirements / Reports, and offers Sign this report…, which opens the file's signatures in Docs. Saving a report does not change the check or the model.
Download HTML saves the report as a web page.
Print / Save as PDF opens the report in a print window: choose Save as PDF there. If the browser blocks the window, allow pop-ups for the site.
A report is not stored unless you save it. To sign it, save it to Docs and sign it there.
BCF Issues
BCF (BIM Collaboration Format) carries issues between BIM tools. OpenBrIM writes the rules that do not pass as a BCF 2.1 file (.bcfzip) for a BCF tool such as BIMcollab, Solibri, Navisworks, Revit or Trimble Connect.
In the Requirements panel, open the ⋯ menu and choose BCF issues…. If there is no check yet, or the last one is out of date, the model is checked first. When the model could not be checked again, the dialog says that the check is out of date and why, also when that check found no issues.
Choose how the issues become topics. Each choice shows how many topics it makes:
One topic per rule: a reviewer works rule by rule; best for a large model;
One topic per object: each object's problem can be assigned on its own.
Click Download .bcfzip, or Save to Docs (under Requirements / Reports).

Open the BCF file beside an IFC exported from this model. Each topic selects its elements by IFC GlobalId, and the export writes the same GlobalIds for the same objects.
BCF issues can also be written from the Export dialog, when the exported file does not pass: Download BCF issues, for the file just written.
Stable topics. In one project, the same issue gets the same topic GUID: topics are keyed by the requirement set's title, the rule and the object's name. When you export the issues again, a BCF server updates each topic instead of adding a new one. Renaming the set or the object starts new topics.
A topic selects at most 200 elements; a larger issue is split into parts titled (2 of 3). A file holds at most 1000 topics. When everything checked passes, there is nothing to write: No issues to write: every rule that was checked passes.
Update a Requirement Set
When the owner issues a new version of a file, upload it over the old one.
In Docs, open the IDS file's ⋯ menu and choose Update…, then pick the new file. Or drop the new file onto the old one in the tree and choose Update….
The Update “…” dialog shows:
Files: the current and the new file, with versions and rule counts;
Changes to the rules: rules Added, Removed and Changed, each in plain language, with its status in this model before and after;
In this project: the data rules met now and with the new file;
Saved fixes: which saved fix decisions carry over and which are dropped because their rule changed.
Click Replace file, or Cancel to keep the current file.

The file keeps its name, role and set. The old content stays stored, so Undo brings it back. If the file was searchable by AI, its new content is indexed in place of the old. Check again to see the new results.
Update… refuses a file that is shown in a set but stored outside the Requirements folder, because replacing it would discard the model's stored analysis and design results. Add the new version to the set with Add files… instead.
Download a readable version
For owners and reviewers who do not read IDS, choose Download readable version in an IDS file's ⋯ menu. It saves an HTML file (<name> - rules.html) with every rule in plain language, its instructions and the saved fixes applied. Print it from the browser to get a PDF.
Requirement Sets in Templates
Upload the requirement sets once into your master template, with any fixes. Every project created from the template starts with them, and values entered on the template's objects stay with those objects by name.
Sets and files that came from the template (or from a project copied to your account) are marked From another project.
A project created earlier keeps the version it was created with. To update it, upload the new file in that project.
Values are part of the project, so a project created from the template, or a copy, keeps whatever was entered in it. Leave values that identify one project (a project number, a letting date, a bridge number) blank in the template.
Limits
Check now checks the model's data without geometry. Rules that read geometry are checked only when the IFC is exported, and not at all for an exported file over about 100 MB.
A check runs by itself only once, after the project opens. It does not run again after later edits or compiles, and results are not saved with the project or on the server.
Only models made in OpenBrIM are checked: an IFC file from other software cannot be checked against the sets.
A few IDS features are not supported and are reported when a file is read: Unicode block escapes in patterns (such as
\p{IsBasicLatin}),xs:whiteSpace,xs:assertionand nested simple types. A pattern too complex to evaluate safely is refused.The file check does not compare property names against the standard
Pset_andQto_tables.Values are kept by the object's name. They survive renaming the object and copying the project, but an object made by copy and paste starts without them. Deleting an object leaves its values under its name, so an object later created with that name (one Generate-in-place re-creates, for example), or an object with no values of its own renamed to it, takes them. An object that has values of its own and is renamed onto such a name keeps its own, and the values kept there are put aside. The Requirements panel lists the names that hold values no object has and the values put aside, also in a project with no requirement set. A rename to a name with
#or starting with@is refused while the object has values, because such a name cannot keep them.Requirement values are entered by hand. Nothing is read from the object's parameters or from analysis results.
Related Pages
Project Requirements for AI Agents: the same work through an AI agent connected to OpenBrIM Desktop, and writing BCF issues from a script.
Interoperability: exporting 3D models, drawings and FEA models.