Pile Capacity Check [SPIG]
General
Template: The code check template is utilized to extract global parameters, results from finite element analysis, and limit states employed in the design process.
Pile Cap: Pile cap, pier or bent for code check. The detailed report will include information about all piles located under the pile cap.
PDF Name (Export): This parameter allows the name of the code check document to be modified when saving it as a PDF. When renaming the file, special attention must be given to the text characters on the linked page, as certain characters may interfere with parametric equations and lead to unexpected results.
Pile Cap Name: Name identifier for the pile cap used in the analysis and reporting.
Factored Result Name: Name identifier for the factored results dataset used in the code check calculations.
Pile Cap Type: Specifies the type of pile cap structure [Footing/End Bent].
Pile Name List: List of all pile names that are part of the pile cap system for analysis.
Pile Capacity List: Array of compression capacities for each pile in the system.
Defined Strength Limit State List: List of strength limit states defined for the design code being used.
Defined Service Limit State List: List of service limit states defined for the design code being used.
Defined All Limit State List: Comprehensive list of all limit states including strength, service, and other applicable limit states.
Footing CAD View Parameters
Footing Polygon 1: Coordinates defining the outline of the footing polygon for visualization.
Footing Longitudinal Offset 1: Longitudinal offset distance for footing display positioning.
Footing Transverse Offset 1: Transverse offset distance for footing display positioning.
Rotation 1: Rotation angle for the footing CAD display.
Center Coordinate 1: Center point coordinates for the footing geometry.
Minimum X 1: Minimum X-coordinate boundary of the footing.
Maximum X 1: Maximum X-coordinate boundary of the footing.
Piles 1: Collection of piles under the footing for display purposes.
Offset Point 1: Reference offset point for footing positioning.
Pile Coordinates Rotated 1: Rotated coordinates of piles relative to footing center.
Pile Global Coordinates: Global coordinates of all piles in the system.
Pile Global Section References: Section references for piles at global coordinates.
Pile Global Names: Names assigned to piles at global coordinates.
End Bent CAD View Parameters
Minimum X: Minimum X-coordinate boundary of the end bent structure.
Maximum X: Maximum X-coordinate boundary of the end bent structure.
Section Width: Width dimension of the end bent section for CAD display.
Rotation: Rotation angle for the end bent CAD display.
Center Coordinate: Center point coordinates for the end bent geometry.
Piles: Collection of piles under the end bent for display purposes.
Pile Global Coordinates EB: Global coordinates of all piles in the end bent system.
Pile Global Section References EB: Section references for piles at global coordinates in end bent.
Pile Global Names EB: Names assigned to piles at global coordinates in end bent.
Last updated