Field Splice Code Check T [SIG]
General
Load Combination Table: The load combination table is used to map the analysis result cases and their corresponding factors to the template, along with the limit states. It serves as the basis for all finite element analysis results used in the code check equations.
Filler F_y: The specified minimum yield strength of the filler plates. Where the flanges or the webs on the two sides of the joint differ in thickness, the splice adds a filler on the thinner side, and the filler's yield strength enters the reduction of the bolt shear resistance for fillers (AASHTO 6.13.6.1.4). Default 50 ksi for a new template.
Run NSBA recommended splice checks: [No/Yes]: Yes adds the checks the NSBA Bolted Field Splices for Steel Bridge Flexural Members recommends beyond AASHTO: the splice plate proportioning requirements and the combined splice plate area. No leaves them out of the report.
Block shear U_bs [0.5/1.0]: Reduction factor for block shear rupture resistance per AASHTO 6.13.4. Takes a value of 0.5 for non-uniform tension stress and 1.0 for uniform tension stress. Only these two values are accepted.
Web splice plate design force: [Vector sum R of V_r and H_w (6.13.6.1.3c)/V_r alone (NSBA worked examples)]: The force the web splice plates are checked for in shear yielding, shear rupture and block shear. The default follows AASHTO 6.13.6.1.3c, which designs the plates and their connections for the vector sum R of the web shear V_r and the horizontal force in the web H_w. V_r alone checks the plates for the shear only, as the NSBA worked examples do.
Last updated