Uniform Temperature Load [TB]
General
Normally, two distinct scenarios should be generated with two stages for contraction and expansion. The AASHTO gradient also has two, a positive and a negative one.
Bridge: Choose the bridge to automatically apply the temperature load on all deck and girder components.
Applied Elements [Superstructure/Superstructure and Substructure]: Selects which parts of the bridge receive the temperature change. Superstructure applies it to the deck and girder components only; Superstructure and Substructure also applies it to the piers, columns, and other substructure elements. With AASHTO Gradient, the substructure takes the uniform temperature calculated below, and only the deck takes the gradient.
Stage: Choose a stage to apply the temperature loading. AASHTO Gradient needs a stage, because without one the load is not applied in a staged model.
Temperature Type [Uniform/AASHTO Gradient]: Uniform applies one temperature change to everything selected. AASHTO Gradient applies the vertical temperature gradient of AASHTO LRFD Article 3.12.3 for steel superstructures, with the dimension A taken as 12 in., T3 as 0 and t as the deck thickness.
AASHTO Gradient is available only when every girder on the bridge is a steel I-girder, or an arbitrary section girder with a steel material. Other girder types, steel tub girders included, are refused with a message. The deck must be at least 4 in. thick, and every deck and girder material needs a thermal coefficient.
Temperature Change From Mean: When dealing with expansion, it is necessary to input a positive temperature value, whereas a negative temperature value should be utilized for contraction. Shown when the temperature type is Uniform.
T1, Top of Deck: The temperature at the top of the deck. Shown when the temperature type is AASHTO Gradient.
T2, 4 in. Below Top of Deck: The temperature 4 in. below the top of the deck. Shown when the temperature type is AASHTO Gradient.
Take the positive values of T1 and T2 from AASHTO LRFD Table 3.12.3-1, for the bridge's solar radiation zone in Figure 3.12.3-1. For the negative gradient, multiply both by −0.30 for a plain concrete deck or −0.20 for a deck with an asphalt overlay.
1
54
14
2
46
12
3
41
11
4
38
9
Uniform Temperature, Except Deck: The temperature applied to everything other than the deck, such as girders, cross-frames, diaphragms and barriers. It is the gradient's value at the bottom of the deck, T2 × (16 − t) / 12, and 0 for a deck 16 in. or thicker. AASHTO does not define a gradient for barriers, so taking this value for them is an assumption. If the deck thickness varies, this value uses the first thickness of the first deck. (Read-only)
Apply to Rigid Elements [No/Yes]: Selects whether rigid elements, such as rigid links, also receive the temperature load.
Last updated