Skip to content
For the complete documentation index, see llms.txt. This page is also available as Markdown.

Lateral Bracing [TB]

Lateral Bracing

A delta frame lateral bracing is one bracing member between the legs of delta frame units (Delta Frame Unit). Each member is its own object, so any bracing layout can be built from them, for example an X brace in the plane of the front legs and another in the plane of the rear legs of two neighbouring units. Each end of the member is a point on a leg, given as a distance along the legs from the W.P. of its unit.

X bracing between the front legs and between the rear legs of two delta frame units

Points as signed distances along the legs

  • Reference point. Each distance is measured along the legs of the unit from its W.P. (the work point where the two legs meet, above the bearing), not along the station.

  • Sign. A positive distance puts the point on the front leg (the ahead-station leg), and a negative distance puts it on the rear leg (the back-station leg). The same value with the other sign is the point at the same distance on the other leg.

  • Allowed values. The distance must be more than zero and no longer than the leg. Zero would be the W.P. itself, where the legs have no finite element node, so the member end would not be connected. The unit shows the length of each leg as Rear Leg Length and Front Leg Length.

  • Layouts. The two points can be on the same side, for example both positive for a member in the plane of the front legs, or on opposite sides, for a diagonal from a front leg to a rear leg. When both points are on the same unit, they must be on different legs (one positive and one negative distance).

Elevation of the legs: the first and the second point of two bracings as signed distances along the legs from the W.P., positive on the front leg and negative on the rear leg

Finite element model and construction

  • The member is a truss or beam element (FE Type) between two nodes on the centerlines of the legs, and the legs get a node at each of these points, so the member is connected to the leg centerlines. In the 3D model the member is also drawn to the leg centerlines, so a short part of its end can show through the web of the leg.

  • The member is in the truss element group of the bridge, so the temperature loads applied to that group reach it.

  • The member is erected by Delta Frame Unit Construction, either with its two units (Between the Selected Units) or picked by name (Selected).

General

First Delta Frame Unit: The unit that the first point of the member is on, picked from the model. A value is required.

Second Delta Frame Unit: The unit that the second point of the member is on, picked from the model. It can be the same unit as the first one only when the two points are on different legs. A value is required.

Bracing Section: Cross section of the member, selected from the sections defined under Properties > Sections. It is used in the 3D model, the finite element model and the quantities. A value is required.

Distance Along Leg - First Point (+ Front / - Rear): Signed distance along the legs of the first unit from its W.P. to the first point: positive on the front leg, negative on the rear leg. The default is 42 in on the front leg. The object reports an issue when the distance is zero or longer than the leg.

Distance Along Leg - Second Point (+ Front / - Rear): Signed distance along the legs of the second unit from its W.P. to the second point: positive on the front leg, negative on the rear leg. The default is -42 in, on the rear leg. The object reports an issue when the distance is zero or longer than the leg.

Section Orientation Angle: Rotation of the section about the axis of the member, in the 3D model and in the finite element model.

Bracing Length (readonly): Length of the member between its two points (Read-only).

FEA

FE Type [Truss/Beam]: Element type of the member in the finite element model. Truss (the default) carries axial force only; Beam also carries bending, shear and torsion.

3D Detailing

Opacity: Transparency of the 3D visualization. Range from 0 (fully transparent) to 1 (fully opaque).

Referencing Objects

Structure States: The Delta Frame Unit Construction objects that pick this member by name under Selected Lateral Bracings (Read-only). A member erected with its two units (Between the Selected Units) is not listed here.

Quantities

Quantities derived from the parameter definitions are exposed as read-only values under this tab.

Cross Section Area: Area of the bracing section (Read-only).

Cross Section Perimeter (outer): Outer perimeter of the bracing section (Read-only).

Min Length Path: Minimum path length along the drawn member (Read-only).

Length @COG Path: Length of the member along its centerline, between its two points (Read-only).

Max Length Path: Maximum path length along the drawn member (Read-only).

Total Surface Area (outer): Outer surface area of the member, its sides and both end faces (Read-only).

Volume: Volume of the member, the section area times the centerline length (Read-only).

Weight: Weight of the member, from its volume and the density of the section material (Read-only).

Material: Name of the material of the bracing section (Read-only).

Section: Name of the bracing section (Read-only).

IFC

Type [IfcBeam/IfcMember/IfcElementAssembly]: IFC entity type for export. The default is IfcMember.

Predefined Type [Brace/Member/Userdefined/Notdefined]: IFC predefined type of the member. The default is BRACE.

Parent [Bridge/Superstructure/Substructure/Foundation]: IFC parent container of the member in the exported model hierarchy. The default is SUBSTRUCTURE.

Properties: Additional IFC properties written to the exported member, one row per property.

Last updated