> For the complete documentation index, see [llms.txt](https://docs.openbrim.org/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://docs.openbrim.org/templates/truss-bridge-workflow/substructure-tb/stm-tb/pier-cap-stm-tb.md).

# Pier Cap STM \[TB]

## Pier Cap STM

The Pier Cap STM object builds the strut-and-tie truss of a pier cap (AASHTO LRFD 9th Edition, 5.8.2) in the finite element model and solves it in its own analysis case. It is the input of the Pier Cap STM Code Check (D-Region).

The top chord lies at the top reinforcement mat and the bottom chord follows the soffit. The supports are the column nodes, with each column split as in AASHTO Figure C5.8.2.2-4. Each bearing sends a direct strut to a support where the strut angle allows it, and a vertical tie is added only where it does not (Figure C5.8.2.2-3). The truss is loaded with the bearing reactions in its Factored Bearing Reactions table and with the factored weight of the cap. The truss geometry is derived from the inputs of the pier cap (its bar rows, materials and soffit line), never from an analysis result.

On a cap with more than one column the truss is externally indeterminate. Once the column force tables are filled, each column's axial force and moment at its top are applied as loads on its nodes and the truss is held by three restraints only, so its forces are set by equilibrium alone (TxDOT 0-5253 Report 5-5253-01-1, 2.8.4).

### General

**Pier Cap:** Pick the pier cap to model. The cap must carry at least one bearing, otherwise the truss has no loaded node; a column rotated relative to the cap is also reported as a validation issue, because the truss takes the column dimension along the cap from its section and that holds only for a column square to the cap. The user must provide a value.

**Load Combination Table:** The load combination table the bearing reactions are read under when Fill from FEA Bearing Reactions is used. The DC load factor of the cap weight is also read from it, for the Reaction Limit State selected below. The user must provide a value.

### Truss Model

**Chord Placement \[Automatic/Both chords at the steel mats/Bottom chord at the compression block/Bottom chord placed for its back face]:** Where the chords of the truss lie. A tie lies at the centroid of its reinforcement (C5.8.2.2); a chord that carries only compression lies at the compression stress block (5.8.2.5.2).

* **Automatic** (default): Both chords at the steel mats on a cap with more than one column, where the bottom chord is a tie between the columns; on one column, the bottom chord placed for its back face.
* **Both chords at the steel mats:** The top and bottom chords lie at the centroids of the top and bottom reinforcement mats.
* **Bottom chord at the compression block:** The bottom chord lies at the middle of the compression block that balances the top mat at yield. On one column this back face fails whenever the tie force exceeds about 70 percent of A\_s f\_y.
* **Bottom chord placed for its back face:** The bottom chord is raised just enough for the back face of the node at the column face to resist the force (5-5253-01-1, 2.10.4), and never below the compression block.

**Strut Layout \[Direct struts where the angle allows/Vertical tie at every bearing]:** How the bearing loads reach the supports. With Direct struts where the angle allows (default), each bearing sends a strut directly to a support, and a vertical tie is added only where the strut angle would be too flat. With Vertical tie at every bearing, every bearing load is first carried by a vertical tie.

**Cap Weight on the Truss \[Lumped at every station/Lumped at the loaded top nodes]:** How the factored cap weight is applied to the truss. With Lumped at every station (default), each truss station takes the cap from the midpoint to the station before it to the midpoint to the station after it, and the first and last stations also take the cap out to its ends; at a support the weight goes on the bottom node, where the cap sits on the column. With Lumped at the loaded top nodes, the loaded top nodes take the weight instead, each the cap between the midpoints to its neighboring loaded nodes (5-5253-01-1, Examples 1 and 2).

### Column Bars

These inputs describe the column bars that anchor a column tie, where a column carries a moment large enough to put part of its section in tension. They are read from the line-layout bars of the column, the rows on its faces along the cap; a column without them uses the values below.

**Column Tension-Face Bar Area (columns without line-layout bars):** The bar area on the tension face of a column that has no line-layout bars.

**Column Tension-Face Bar Centroid From the Face (columns without line-layout bars; 0 = a tenth of the column width):** The distance from the column face to the centroid of those bars. Zero uses a tenth of the column width.

### Truss Analysis

**Factored Bearing Reactions, written by Fill from FEA:** The bearing reactions that load the truss: one row per loading scenario and one column per bearing, in the order of the cap's bearings. A row needs a value for every bearing, and the table holds at most twenty bearings. The code check reads the first row only, so a second row is reported by a check. The table can be typed, pasted, or written by the **Fill from FEA Bearing Reactions** cell action, which needs analysis results: it reads the bearing reactions of the bridge analysis under the Load Combination Table, Reaction Limit State and Reaction Basis below and writes the row and the Extraction Status. A cap without girders has no bearing springs to read, so its table is typed.

**Reaction Limit State \[Strength I/Strength II/Strength III/Strength IV/Strength V/Extreme Event I/Extreme Event II/Service I/Service II/Service III/Service IV/Fatigue I/Fatigue II]:** The limit state the bearing reactions are read under, and whose DC factor is applied to the cap weight. When the Load Combination Table has no such limit state, the AASHTO Table 3.4.1-2 factor is used: 1.50 for Strength IV, 1.25 for the other Strength and Extreme Event combinations, 1.00 for Service and 0 for Fatigue. The default is Strength I. Use a Strength or Extreme Event limit state: a check flags any other, because 5.8.2 is checked with the resistance factors of 5.5.4.2. Under an Extreme Event limit state only the vertical bearing reactions are read, so horizontal bearing forces are not on the truss.

**Maximized Bearing \[None/Bearing 1/Bearing 2/.../Bearing 20]:** The bearing whose reaction is maximized when the reactions are read concurrently. Available when Reaction Basis is Concurrent with maximized bearing.

**Reaction Basis \[Governing maximum/Governing minimum/Envelope of both/Concurrent with maximized bearing]:** Which set of reactions Fill from FEA Bearing Reactions reads.

* **Governing maximum** (default): The maximum reaction of each bearing.
* **Governing minimum:** The minimum reaction of each bearing; the cap weight then takes the minimum DC factor.
* **Envelope of both:** The envelope of the maximum and minimum reactions.
* **Concurrent with maximized bearing:** The reactions of all bearings concurrent with the maximum reaction of the Maximized Bearing.

**Extraction Status:** The result of the last Fill from FEA Bearing Reactions, written by the cell action. (Read-only)

### Column Forces

These tables are used only on a cap with more than one column and are available only there. Type them from the bridge analysis, one row per loading scenario in the same order as the bearing reaction rows and one column per pier column in the order of the pier cap's column list, for the load state of the bearing row (concurrent with the maximized bearing). Until they hold forces for every column, every column node is a support and the code check reports its result as invalid. On such a cap the Reaction Basis must be Concurrent with maximized bearing, so that the column forces and the bearing reactions are one load state, and a check confirms that the typed forces balance the bearing loads and the cap weight (vertical force within 2 percent, resultant position within 2 percent of the cap length). Fill from FEA Bearing Reactions does not fill these tables.

**Factored Axial Force at the Top of Each Column (compression positive), typed:** The axial force each column pushes up on the cap, compression positive.

**Factored Moment at the Top of Each Column in the Plane of the Cap (positive raises the reaction at the higher-station half), typed:** The moment at the top of each column in the plane of the cap, positive where it raises the reaction on the half of the column at the higher station.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://docs.openbrim.org/templates/truss-bridge-workflow/substructure-tb/stm-tb/pier-cap-stm-tb.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.