Pier Cap STM Code Check Template [TB]
Pier Cap STM Code Check Template
The Pier Cap STM Code Check Template holds the project-wide settings of the strut-and-tie check of pier caps per AASHTO LRFD 9th Edition, 5.8.2. Each Pier Cap STM Code Check (D-Region) object points at one template, so these values do not have to be repeated for every pier cap. The check applies AASHTO 5.8.2 only; there is no state provision option.
The Pier Cap STM truss does not reference this template: its own Load Combination Table input sets the combination its bearing reactions and cap weight factor are read under.
General
Load Combination Table: The load combination table that maps the analysis result cases and their factors to the limit states used by the check. The user must provide a value.
Design Parameters
Resistance Factor, Compression in STM: The resistance factor φ applied to the compressive resistance of struts and node faces in a strut-and-tie model, per AASHTO LRFD 5.5.4.2 as required by 5.8.2.3. The default is 0.70. It must be greater than 0 and not more than 1.
Resistance Factor, Tension in STM: The resistance factor φ applied to the tensile resistance of the ties in a strut-and-tie model, per AASHTO LRFD 5.5.4.2 as required by 5.8.2.3. The default is 0.90. It must be greater than 0 and not more than 1.
Last updated